Operations Manual UWEX
®
722 C 17
_________________________________________________________________________
___________________________________________________________________
© 2005, Ebinger Prüf- und Ortungstechnik GmbH.
Pic. 7: coarse adjuster for sensitivity inside battery compartment
8. Using the detector
To inspect an area carry search head in scanning movement flat and parallel over
ground. Make sure that searched strips overlap and avoid dead spots. The detector
operates on a static mode showing metal objects by an audio alarm as long as the
search head is held over a detected object. The intensity of the signal corresponds to the
signal strength received from the target. Objects provide the strongest signal when the
search head centres over a target.
Small objects at close distance will generate a strong but short peak signal, which is
spread over a small surface. Several small objects generate a wide spread signal.
Large targets even if buried at depth will generate a signal spread over a large surface.
A B
A - Signal shape for a small shell lying horizontally
B – Signal for a large object
Fig. 4 different detection alarm signals
If the audio signal is spread over a large area lift search coil to improve pinpointing and
determination of size and distance of the located metal.